000 03655nam a22003497a 4500
003 OSt
005 20240306054908.0
008 240306b ||||| |||| 00| 0 eng d
040 _bEnglish.
_cCvSU-CCAT Campus Library.
_erda.
050 _aUM TK 7872.D48
_bC39 2022
100 _aCayetano, Marian Allyssa S., author
_99033
245 _aSolar powered automated aquaculture monitoring and filtration of heavy mentals in reshwater /
_cMarian Allysa S. Cayetano, Vergilio T. Mina, John Airon A. Morano, and Kimchin E. Palomar.
260 _aRosario, Cavite :
_bCavite State University-CCAT Campus,
_c2022.
300 _axvi, 62 leaves :
_billustrations ;
_c28 cm
500 _aA design project (BSEE)--Cavite State University-CCAT Campus, 2022.
504 _aIncludes bibliographical references and appendices.
520 _aMARIANE ALLYSSA S. CAYETANO, VERGILLO T. MINA, JOHN AIRON A. MORANO, AND KIMCHIN E PALOMAR. This study would not have been possible without the collaboration of various individuals who pooled their resources and ideas to make this endeavor a reality. Undergraduate Design Project. Bachelor of Science in Electrical Engineering. Cavite State University -Cavite College of Arts and trades, Rosario, Cavite, June 2022. adviser: Engr. Joel C. Gammayao. Technical Critic: Engr. Michael M, Ramos This study aimed to make the monitoring and filtration process for possible detection of heavy metals more convenient and to introduce modern technology to traditional aquafarmers. This is an innovative water monitoring and filtration with GSM-based technology that supports production of good quality of fish farm products. and food safety. The study composed of three primary system which are power supply monitoring system, and filtration system. It was designed and fabricated with a total dimension of 100cm x 50 cm x 2.54cm. The machine was tested, specifically the individual sensors used to monitor water, for its functionality through speed and accuracy test. For the analysis and evaluation of the data collected after testing, a statistical instrument was used. Furthermore, the data was transformed into descriptive statistic that is used to examine and bring a conclusion to the data. The testing results show that the average reading after 30seconds are 8.91, 4.72 NTU, and 1510.8 ppm for pH, turbidity , and TDS respectively. Meanwhile, after 60s seconds the readings for pH, turbidity, and TDS are 8.94, 4.63 NTU, and 1495 ppm respectively. Lastly after 90 seconds the reading for pH is 8.99, turbidity is 4.87, and TDS is 1494.22 ppm. Based from the findings of this study, it was concluded that developing an automated aquaculture monitoring and filtration technology can be helpful to aquafarmers in securing production of aquafarm products free from possible contamination of toxic substances, specifically heavy metals. Sensor in this study were effectively used in monitoring the water and determining if set parameters were exceeded. The study cost almost ₱33,766.00
546 _aIn English text.
650 _aWater purification.
_99034
650 _aWater treatment.
_95210
650 _aHeavy metal removal.
_99035
650 _aMonitoring.
_95482
650 _aWater remote sensing.
_99036
650 _aDetectors.
_94871
700 _aMina, Vergilio T., author.
_99037
700 _aMorano, John Airon A., author.
_99038
700 _aPalomar, Kimchin E., author.
_99039
700 _aGammayao, Joel C., adviser.
_99040
700 _aRamos, Michael Jr M., technical critic.
_99041
942 _2lcc
_cT/M/D
_hTK 7872.D48 C39 2022
_kUM
999 _c2729
_d2729