000 03109nam a22003137a 4500
003 OSt
005 20220622005250.0
008 220622b ||||| |||| 00| 0 eng d
040 _bEnglish.
_cCvSU-CCAT Campus Library.
_erda.
050 _aUM TJ 223.76
_bB75 2017
100 _aBriones, Rey H., author
_95515
245 _aDevelopment of Multiple Access Electromagnetic Door Lock Control System /
_cRey H. Briones, Darwin John G. Suck and Ronell D. Viray.
260 _aRosario, Cavite :
_bCavite State University-CCAT Campus,
_c2017
300 _axiii, 55 leaves :
_billustrations ;
_c28 cm
500 _aDesign Project (BSCpE)--Cavite State University-CCAT Campus, 2017.
504 _aIncludes bibliographical references and appendices.
520 _aBRIONES, REY H., SUCK, DARWIN JOHN G., VIRAY, RONELL D., Development of Multiple Access Electromagnetic Door Lock Control System. A Project Design. Bachelor of Science in Computer Engineering, Cavite State University Rosario, Rosario, Cavite. April, 2017. Thesis Adviser: Mrs. Diane P. Araya. Technical critic: Jurick P. Paulino. The general objective of the study was to develop an Electromagnetic Door Lock Access Control System. Specifically, the study aimed to design the circuits and software interface of the Multiple Access Electromagnetic Door Lock Control System, construct the hardware by using Arduino microcontroller; test and evaluate the performance of the Multiple Access Electromagnetic Door Lock Control System in terms of the response rate and response tune of the access control modes; and implement the Multiple Access Door Lock Control System m the RECETS Office of Cavite State University Rosario Campus. The prototype is a microcontroller-based system that supports its entire access control. Arduino Sketch was used to code the function of all the access control modes and other components contained in the prototype. Finger print scanner, GSM phone call and smart card were the access control modes that were used by the prototype in authentication for granting or denying every access made by a requester. All the access information made by any requester (access history) was stored in the control system’s database. The prototype has an alarm that was triggered whenever an unauthorized access occurred. The performance of the prototype was being evaluated using Performance Evaluation where the response rate and response time of the access control modes were tested. The most used access control mode was observed through collected data of the control system’s storage application.
650 _aArduino (Programmable controller).
_92867
650 _aMicro-controller based.
_95516
650 _aElectronic security systems.
_95517
650 _aFingerprint scanner.
_95470
650 _aAuthentication.
_95518
700 _aSuck, Darwin John G., author.
_95519
700 _aViray, Ronell D., author.
_95520
700 _aArayata, Diane P., adviser.
_95429
700 _aPaulino, Jurick P., critic.
_95479
942 _2lcc
_cT/M/D
_hTJ 223.76
_iB75 2017
_kUM
999 _c1756