245 _aThree-phase generator synchronizing trainer /
_cJohn Michael L. Legacion, [and three others]
260 _aRosario, Cavite :
_bCavite State University-CCAT Campus,
_c2019
300 _axv, 50 leaves :
_billustrations ;
_c28 cm
500 _aUndergraduate Project Design (BSEE)--Cavite State University-CCAT Campus, 2019.
504 _aIncludes bibliographical references and appendices.
520 _aLEGACION, JOHN MICHAEL L., NIVIAR, MARVIN V., NUAL, CRISTOPHER R, TITO, LORRAINE A. Three-phase generator synchronizing trainer. Undergraduate Design Project. Bachelor of Science in Electrical Engineering. Cavite State University - Cavite College of Arts and Trades Campus, Rosario, Cavite. June 2019. Adviser: Engr. Alvin A Castro. Technical Critic: Prof. Noelle T. Legaspi. The study was conducted from August 2018 to March 2019 to develop a three ­phase generator to grid synchronizing trainer Specifically this study aims to: 1. design and construct a trainer for synchronizing AC generator. lt focuses on synchronizing two alternators where an alternator will connect in parallel to the other alternator that is in live system of constant voltage and constant frequency. 2. test and evaluate the proposed trainer in terms of its functionality, construction, effectiveness, reliability and safety. Lastly, assess the trainer to comply with the electrical standards. The trainer was constructed with individual digital meters that are used to test alternators like short circuit test, open circuit test and de resistance test. Digital multi-meters were constructed to check the voltage magnitude and frequency of the incoming generator and bus generator. The system uses synchroscope to check the voltage difference, frequency difference, phase sequence and phase angle between the incoming generator and bus generator. A synchronizing switch is use to switch on or make contact between alternators and grid source when it completely meets the condition of synchronizing. The results of the evaluation revealed that the three-phase generator synchronizing trainer is feasible and reliable.
650 _aElectric generator
_xAlternating current.
_94798
650 _aElectric generator
_xDesign and construction.
_94799
650 _aSynchronous generator.
_94800
650 _aElectric wiring.
_9900
700 _aLegacion, John Michael L., author
_94698
700 _aNiviar, Marvin V., author
_95217
700 _aNual, Christopher B., author
_95218
700 _aTito, Lorraine A., author
_95219
700 _aCastro, Alvin A., adviser
_94698
700 _aLegaspi, Noelle T., critic
_94796
942 _2lcc
_cT/M/D
_hTK 2761
_iL44 2019
_kUM
999 _c1601
_d1601