| 000 | 02979nam a22003137a 4500 | ||
|---|---|---|---|
| 003 | OSt | ||
| 005 | 20220615013418.0 | ||
| 008 | 220420b ||||| |||| 00| 0 eng d | ||
| 040 |
_bEnglish. _cCvSU-CCAT Campus Library. _erda. |
||
| 050 |
_aUM TK 2761 _bL44 2019 |
||
| 245 |
_aThree-phase generator synchronizing trainer / _cJohn Michael L. Legacion, [and three others] |
||
| 260 |
_aRosario, Cavite : _bCavite State University-CCAT Campus, _c2019 |
||
| 300 |
_axv, 50 leaves : _billustrations ; _c28 cm |
||
| 500 | _aUndergraduate Project Design (BSEE)--Cavite State University-CCAT Campus, 2019. | ||
| 504 | _aIncludes bibliographical references and appendices. | ||
| 520 | _aLEGACION, JOHN MICHAEL L., NIVIAR, MARVIN V., NUAL, CRISTOPHER R, TITO, LORRAINE A. Three-phase generator synchronizing trainer. Undergraduate Design Project. Bachelor of Science in Electrical Engineering. Cavite State University - Cavite College of Arts and Trades Campus, Rosario, Cavite. June 2019. Adviser: Engr. Alvin A Castro. Technical Critic: Prof. Noelle T. Legaspi. The study was conducted from August 2018 to March 2019 to develop a three phase generator to grid synchronizing trainer Specifically this study aims to: 1. design and construct a trainer for synchronizing AC generator. lt focuses on synchronizing two alternators where an alternator will connect in parallel to the other alternator that is in live system of constant voltage and constant frequency. 2. test and evaluate the proposed trainer in terms of its functionality, construction, effectiveness, reliability and safety. Lastly, assess the trainer to comply with the electrical standards. The trainer was constructed with individual digital meters that are used to test alternators like short circuit test, open circuit test and de resistance test. Digital multi-meters were constructed to check the voltage magnitude and frequency of the incoming generator and bus generator. The system uses synchroscope to check the voltage difference, frequency difference, phase sequence and phase angle between the incoming generator and bus generator. A synchronizing switch is use to switch on or make contact between alternators and grid source when it completely meets the condition of synchronizing. The results of the evaluation revealed that the three-phase generator synchronizing trainer is feasible and reliable. | ||
| 650 |
_aElectric generator _xAlternating current. _94798 |
||
| 650 |
_aElectric generator _xDesign and construction. _94799 |
||
| 650 |
_aSynchronous generator. _94800 |
||
| 650 |
_aElectric wiring. _9900 |
||
| 700 |
_aLegacion, John Michael L., author _94698 |
||
| 700 |
_aNiviar, Marvin V., author _95217 |
||
| 700 |
_aNual, Christopher B., author _95218 |
||
| 700 |
_aTito, Lorraine A., author _95219 |
||
| 700 |
_aCastro, Alvin A., adviser _94698 |
||
| 700 |
_aLegaspi, Noelle T., critic _94796 |
||
| 942 |
_2lcc _cT/M/D _hTK 2761 _iL44 2019 _kUM |
||
| 999 |
_c1601 _d1601 |
||