| 000 | 02808nam a22003017a 4500 | ||
|---|---|---|---|
| 003 | OSt | ||
| 005 | 20230504021356.0 | ||
| 008 | 220419b ||||| |||| 00| 0 eng d | ||
| 040 |
_bEnglish. _cCvSU-CCAT Campus Library. _erda. |
||
| 050 |
_aUM TK 1001 _bT67 2017 |
||
| 100 |
_aTorres, Frenslyn A., author _94772 |
||
| 245 |
_aDevelopment of Single Phase to Three Phase AC Electrical Power Converter with Monitoring Relay / _cFrenslyn A. Torres |
||
| 260 |
_aRosario, Cavite : _bCavite State University-CCAT Campus, _c2017 |
||
| 300 |
_axi, 35 leaves : _billustrations ; _c28 cm |
||
| 500 | _aProject Design (BSEE)--Cavite State University-CCAT Campus, 2017. | ||
| 504 | _aIncludes bibliographical references and appendices. | ||
| 520 | _aTORRES, FRENSLYN A. Development of Single Phase to Three Phase AC Electrical Power Converter with Monitoring Relay. Design Project of Bachelor of Science in Electrical Engineering. Cavite State University-Rosario Campus, Rosario, Cavite. April 2017. Adviser: Engr. Robert G. Briones. Technical Critic: Mr. Jurick P. Paulino. The study was conducted from November 2016 until December 2017 to develop and evaluate single phase to three phase ac electrical power converter with phase monitoring relay Specifically, it aimed to: 1.) design and construct a single phase to three phase ac electrical power converter with phase monitoring relay; and 2.) evaluate the accuracy of the prototype using two-tail test assuming the variance is unequal. The project was focused on the conversion of single-phase electrical power supply to three-phase through three-phase induction motor and has the capability to monitor output voltage, protecting the load and devices itself. lt undergone several stages of research and development process from the conceptualization, construction and testing to the final troubleshooting of the device. The project successfully demonstrated the conversion of single phase to three phase AC electrical power through the use of three phase motor especially controlled by contactors. The output voltage obtained with used of 15, 45 and 900 microfarads capacitors. The project accessibility obtained, yet it was concluded that as recommendation, the use of ammeter and greater horse power rating of idler motor further improved the project capability. | ||
| 650 |
_aSingle Phase to three phase AC electrical. _94773 |
||
| 650 |
_aPower converter _xDesign and construction. _94774 |
||
| 650 |
_aElectric power. _94775 |
||
| 650 |
_aEnergy conversion. _94776 |
||
| 650 |
_aPower electronics converters. _94777 |
||
| 650 |
_aMonitoring relay. _94778 |
||
| 700 |
_aBriones, John Robert G., adviser _94727 |
||
| 710 |
_aPaulino, Jurick P., critic _94779 |
||
| 942 |
_2lcc _cT/M/D _hTK 1001 _iT67 2017 _kUM |
||
| 999 |
_c1597 _d1597 |
||