Development of domestic type air conditioning unit chilled water system / (Record no. 1870)

MARC details
000 -LEADER
fixed length control field 03430nam a22003257a 4500
003 - CONTROL NUMBER IDENTIFIER
control field OSt
005 - DATE AND TIME OF LATEST TRANSACTION
control field 20240401193421.0
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION
fixed length control field 220811b ||||| |||| 00| 0 eng d
040 ## - CATALOGING SOURCE
Original cataloging agency CvSU-CCAT Campus Library
Language of cataloging English.
Transcribing agency CvSU-CCAT Campus Library
Description conventions rda.
050 ## - LIBRARY OF CONGRESS CALL NUMBER
Classification number UM TH 7687.7
Item number S53 2018
100 ## - MAIN ENTRY--PERSONAL NAME
Personal name Siya, Joshua Romel R., Author
9 (RLIN) 6286
245 ## - TITLE STATEMENT
Title Development of domestic type air conditioning unit chilled water system /
Statement of responsibility, etc. Joshua Romel R. Siya, Daryl S. Cruz, and Charles Marvin B. Aro.
260 ## - PUBLICATION, DISTRIBUTION, ETC.
Place of publication, distribution, etc. Rosario, Cavite :
Name of publisher, distributor, etc. Cavite State University-CCAT Campus,
Date of publication, distribution, etc. 2018.
300 ## - PHYSICAL DESCRIPTION
Extent xvi, 84 leaves :
Other physical details illustrations ;
Dimensions 28 cm
500 ## - GENERAL NOTE
General note Design Project Study (BSIT) Major in Refrigerator and Air Conditioning Technology and Stationary Marine Technology--Cavite State University-CCAT Campus, 2018.
504 ## - BIBLIOGRAPHY, ETC. NOTE
Bibliography, etc. note Includes bibliographical references and appendices.
520 ## - SUMMARY, ETC.
Thesis Abstract <a href="ABSTRACT<br/><br/>SIYA, JOSHUA ROMEL R. CRUZ, DARYL S. and ARO,CHARLES MARVIN B. Development of Domestic Type Air Conditioning Unit Chilled Water System. Undergraduate Design Project. Bachelor of Science in Industrial Technology. Cavite State University Rosario Campus, Rosario, Cavite. March 2017. Adviser: Mr. Nestor M. Alvarez. Technical critic: Mr. Regie C. Delos Reyes.<br/><br/><br/>The project study was conducted at Cavite State University-Rosario, Rosario Campus at the Refrigeration and Air Condition Technology Building from October 2015 to March 2017. Specifically, it aimed to do the following:1.)design a chilled water system domestic type air conditioning unit 2.) construct chilled water system domestic type air conditioning unit;3.) evaluate the performance of prototype in terms of its technical performance in terms of the following: cooling efficiency, water temperature, air velocity and amperage of the system; and compare the cooling efficiency and amperage of a domestic type air conditioning unit with same horsepower to the develop project;4.) Conduct cost analysis of the project. <br/><br/><br/>This project study was conducted to produce a new technological device that will help students to learn the principle of air conditioning, the electrical and mechanical parts of the air conditioning system and the chilled water system in the modern day. A domestic type air conditioning unit that will use water as a secondary refrigerant. <br/><br/><br/>The domestic type chilled water system air conditioning unit has a minimum and maximum chilling temperature. The minimum chilling temperature ranged from 14.7℃ to 15℃ and the maximum chilling temperature ranged from 10.9 ℃ to 11°℃. Also the minimum amount of water in water storage was 12 liters and the maximum was 16 liters. The cooling capacity of the said project study ranged from 25.4°C to 23.7C and limited in a room with 32 to 33 cubic meters. The total cost of the project was PHP. 30,312.25<br/><br/>">ABSTRACT<br/><br/>SIYA, JOSHUA ROMEL R. CRUZ, DARYL S. and ARO,CHARLES MARVIN B. Development of Domestic Type Air Conditioning Unit Chilled Water System. Undergraduate Design Project. Bachelor of Science in Industrial Technology. Cavite State University Rosario Campus, Rosario, Cavite. March 2017. Adviser: Mr. Nestor M. Alvarez. Technical critic: Mr. Regie C. Delos Reyes.<br/><br/><br/>The project study was conducted at Cavite State University-Rosario, Rosario Campus at the Refrigeration and Air Condition Technology Building from October 2015 to March 2017. Specifically, it aimed to do the following:1.)design a chilled water system domestic type air conditioning unit 2.) construct chilled water system domestic type air conditioning unit;3.) evaluate the performance of prototype in terms of its technical performance in terms of the following: cooling efficiency, water temperature, air velocity and amperage of the system; and compare the cooling efficiency and amperage of a domestic type air conditioning unit with same horsepower to the develop project;4.) Conduct cost analysis of the project. <br/><br/><br/>This project study was conducted to produce a new technological device that will help students to learn the principle of air conditioning, the electrical and mechanical parts of the air conditioning system and the chilled water system in the modern day. A domestic type air conditioning unit that will use water as a secondary refrigerant. <br/><br/><br/>The domestic type chilled water system air conditioning unit has a minimum and maximum chilling temperature. The minimum chilling temperature ranged from 14.7℃ to 15℃ and the maximum chilling temperature ranged from 10.9 ℃ to 11°℃. Also the minimum amount of water in water storage was 12 liters and the maximum was 16 liters. The cooling capacity of the said project study ranged from 25.4°C to 23.7C and limited in a room with 32 to 33 cubic meters. The total cost of the project was PHP. 30,312.25<br/><br/></a>
546 ## - LANGUAGE NOTE
Language note In English text.
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element Chilled water system domestic type air conditioning unit
9 (RLIN) 6287
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element Air conditioning.
9 (RLIN) 365
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element Prototype, Engineering.
9 (RLIN) 5310
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element Temperature.
9 (RLIN) 5524
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element Cost analysis.
9 (RLIN) 5484
700 ## - ADDED ENTRY--PERSONAL NAME
Personal name Cruz, Daryl S., author.
9 (RLIN) 6288
700 ## - ADDED ENTRY--PERSONAL NAME
Personal name Aro, Charles Marvin B., author.
9 (RLIN) 6289
700 ## - ADDED ENTRY--PERSONAL NAME
Personal name Alvarez, Nestor M., adviser.
9 (RLIN) 5915
700 ## - ADDED ENTRY--PERSONAL NAME
Personal name Delos Reyes, Regie C., technical critic.
9 (RLIN) 6290
942 ## - ADDED ENTRY ELEMENTS (KOHA)
Koha item type Thesis/Manuscripts/Dissertations
Classification part TH 7687.7 S53 2018
Call number prefix UM
Source of classification or shelving scheme Library of Congress Classification
Holdings
Withdrawn status Lost status Source of classification or shelving scheme Damaged status Not for loan Collection code Home library Current library Shelving location Date acquired Coded location qualifier Full call number Barcode Date last seen Copy number Price effective from Koha item type
    Library of Congress Classification     Thesis/Manuscript/Dissertation Cavite State University - CCAT Campus Cavite State University - CCAT Campus TH 08/11/2022 UM UM TH 7687.7 S53 2018 T0003614 10/24/2025 c.1 08/11/2022 Thesis/Manuscripts/Dissertations
    Library of Congress Classification     Thesis/Manuscript/Dissertation Cavite State University - CCAT Campus Cavite State University - CCAT Campus TH 08/11/2022 UM UM TH 7687.7 S53 2018 T0005249 10/24/2025 c.2 08/11/2022 Thesis/Manuscripts/Dissertations