Development of Monitoring System for Communal Water Distribution Network / (Record no. 1782)

MARC details
000 -LEADER
fixed length control field 02669nam a22002537a 4500
003 - CONTROL NUMBER IDENTIFIER
control field OSt
005 - DATE AND TIME OF LATEST TRANSACTION
control field 20220624030649.0
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION
fixed length control field 220624b ||||| |||| 00| 0 eng d
040 ## - CATALOGING SOURCE
Language of cataloging English.
Transcribing agency CvSU-CCAT Campus Library.
Description conventions rda.
050 ## - LIBRARY OF CONGRESS CALL NUMBER
Classification number UM TD 491
Item number T65 2019
100 ## - MAIN ENTRY--PERSONAL NAME
Personal name Toledo, Ivan Joshua N., author.
9 (RLIN) 5691
245 ## - TITLE STATEMENT
Title Development of Monitoring System for Communal Water Distribution Network /
Statement of responsibility, etc. Ivan Joshua N. Toledo.
260 ## - PUBLICATION, DISTRIBUTION, ETC.
Place of publication, distribution, etc. Rosario, Cavite :
Name of publisher, distributor, etc. Cavite State University-CCAT Campus,
Date of publication, distribution, etc. 2019
300 ## - PHYSICAL DESCRIPTION
Extent xi, 37 leaves :
Other physical details illustrations ;
Dimensions 28 cm
500 ## - GENERAL NOTE
General note Design Project (BSCpE)--Cavite State University-CCAT Campus, 2019.
504 ## - BIBLIOGRAPHY, ETC. NOTE
Bibliography, etc. note Includes bibliographical references and appendices.
520 ## - SUMMARY, ETC.
Thesis Abstract <a href="TOLEDO, IVAN JOSHUA N. Development of Monitoring System for Communal Water Distribution Network. Design Project. Department of Engineering. Cavite State University-Cavite College of Arts and Trades Campus, Rosario, Cavite. January 2019. Adviser: Engr. Juniel M. Arcal and Technical Critic. Engr. Ruth Angel L. Burton. <br/><br/>The study was conducted from November 27, 2017 to December 2018 to develop a monitoring system for communal water distribution network. Specifically, the study aimed to; 1) Design and construct the software and hardware of the water quality Monitoring system; 2) Evaluate the performance of system in monitoring pH, TDS sad Water usage: 3) Compare the data gathered of the system to the existing measuring devices for the pH, TDS and water consumption to ensure validity/ reliability of date, and 4) Conduct cost analysis of the system. <br/><br/>A water source from the pump of administration building of Cavite State University - CCAT Campus was used for the technical evaluation of the device. The device has a dimension of 0 15a x 0 08m x 0 07m. Every hour the second reading for the sensors were taken. Sensor readings for TDS and pH depends on the time of the raspberry pi. The 4 x 20-character LCD displays water consumption. Standards for drinking water was set as a range for triggering the solenoid valve. The water hardness result depends on the value of the TDS. <br/><br/>The system can precisely monitor the water quality parameters. A water pressure is required in order to gather data of sensors because the sensors are slightly elevated inside the pipes. Transferring of data from the device to any flash drive is safe.">TOLEDO, IVAN JOSHUA N. Development of Monitoring System for Communal Water Distribution Network. Design Project. Department of Engineering. Cavite State University-Cavite College of Arts and Trades Campus, Rosario, Cavite. January 2019. Adviser: Engr. Juniel M. Arcal and Technical Critic. Engr. Ruth Angel L. Burton. <br/><br/>The study was conducted from November 27, 2017 to December 2018 to develop a monitoring system for communal water distribution network. Specifically, the study aimed to; 1) Design and construct the software and hardware of the water quality Monitoring system; 2) Evaluate the performance of system in monitoring pH, TDS sad Water usage: 3) Compare the data gathered of the system to the existing measuring devices for the pH, TDS and water consumption to ensure validity/ reliability of date, and 4) Conduct cost analysis of the system. <br/><br/>A water source from the pump of administration building of Cavite State University - CCAT Campus was used for the technical evaluation of the device. The device has a dimension of 0 15a x 0 08m x 0 07m. Every hour the second reading for the sensors were taken. Sensor readings for TDS and pH depends on the time of the raspberry pi. The 4 x 20-character LCD displays water consumption. Standards for drinking water was set as a range for triggering the solenoid valve. The water hardness result depends on the value of the TDS. <br/><br/>The system can precisely monitor the water quality parameters. A water pressure is required in order to gather data of sensors because the sensors are slightly elevated inside the pipes. Transferring of data from the device to any flash drive is safe.</a>
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element Water-pipes-monitoring.
9 (RLIN) 5692
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element Water
General subdivision Distribution
Form subdivision Quality control.
9 (RLIN) 5693
700 ## - ADDED ENTRY--PERSONAL NAME
Personal name Arcal, Juniel M., adviser.
9 (RLIN) 5669
700 ## - ADDED ENTRY--PERSONAL NAME
Personal name Burton, Ruth Angeli L., critic.
9 (RLIN) 5694
942 ## - ADDED ENTRY ELEMENTS (KOHA)
Source of classification or shelving scheme Library of Congress Classification
Koha item type Thesis/Manuscripts/Dissertations
Classification part TD 491
Item part T65 2019
Call number prefix UM
Holdings
Withdrawn status Lost status Source of classification or shelving scheme Damaged status Not for loan Collection code Home library Current library Shelving location Date acquired Total Checkouts Full call number Barcode Date last seen Copy number Price effective from Koha item type
    Library of Congress Classification     Thesis/Manuscript/Dissertation Cavite State University - CCAT Campus Cavite State University - CCAT Campus TH 06/24/2022   UM TD 491 T65 2019 T0005203 10/24/2025 1 copy 06/24/2022 Thesis/Manuscripts/Dissertations